Plastics and Insulating Materials- Containing the risk in hazardous areas

January 20th, 2010

Traditionally, flammable liquids have been transported in metal drums and the need to earth these during filling and emptying operations, in order to prevent the build up of static electricity, is generally well known. Likewise, powders were often stored in paper sacks or fiber kegs, which allow a reasonable degree of static dissipation.

Over the past few years, the need to improve efficiency has often led to materials being stored and moved in larger bulk. Today, it is quite common for liquids to be transported in 1000-liter containers, and powders in 1 tonne bags, both of which are approximately 1 meter cubed. These larger containers are generally produced from moulded plastic, as with IBCs (Intermediate Bulk Containers), and polypropylene fabric in the case of FIBCs (Flexible Intermediate Bulk Containers). Often pipes used to transfer these products are lined with plastic or PTFE, for corrosion resistance, hygiene or avoidance of contamination. This use of insulating materials presents three areas of risk in flammable atmospheres:

1) The liquid or powder in the container is likely to have built up an electro-static charge during the transfer operation, and even a conductive material will retain its charge, as the container or pipe will prevent it from flowing back to earth. This could lead to a static discharge from the surface of the material if, for example, it was approached by an earthed container for sampling.

2) An insulating container will gather charge during filling, in a similar manner to an unearthed metal one. When the electro-static field reaches the breakdown strength of air, a brush discharge could occur at the container surface. Whilst likely to be less energetic than a spark from unearthed metal, it will still ignite many solvent vapours and occasionally, certain dust clouds, particularly the low MIE powders used in modern pharmaceutical operations.

3) The container could allow metal parts, such as its tap, to become isolated conductors, which could give rise to energetic spark discharges. Even a tool placed on top of a plastic IBC could become charged and spark to the unit’s metal strengthening frame. Large plastic containers can also cause a charge to be induced on nearby objects or personnel. This is particularly true of insulating FIBCs.

Ensuring Safety - Controlling the Risk
Owing to developments in materials technology, it is now possible to obtain plastic kegs, large IBCs, FIBCs and pipe grounding paddles, specifically designed for use in hazardous areas. Large plastic IBCs are now available with a complete steel shroud, in addition to their strengthening cage, which will prevent discharges from their surface, providing they have been suitably earthed using a discharge lead and clamp. They also have a conductive valve, protruding into the liquid, to give a static dissipation path. Using a different approach, but giving a similar result, kegs are now being produced from plastics that contain a conductive substance, usually carbon. These should have an electrical resistance of less than 1×10^8 ohms, and are designed to dissipate static electricity. This will prevent the risk of brush discharges from their surface, and will give a path for electrical discharge of their contents.
In all cases, these type of containers should be suitably earthed using either a discharge lead, clamp, or in the case of the kegs, by being in contact with an earthed metal plate. FIBCs have now been categorised into four categories, A, B, C and D by the Swiss Institute of Safety and Security. The type C variety contains thin conductive strips spaced closely together in the polypropylene weave. All these strips are interconnected at the seams, and via the lifting handles and a labeled earthing point. These conductive parts will carry away any static electricity on the surface of the bag, and provide a path to dissipate static electricity from the powders within. Type C bags have been proved to be safe for use in flammable atmospheres, providing they have been earthed using a suitable discharge lead and clamp, such as the special FIBC clamp. A common worry with these bags is the uncertainty of whether or not an earth has actually been achieved, and a solution to this problem has been found in the Cenelectrex Earth-Rite FIBC system, which was specially designed to work with static-dissipative plastics, including type C FIBCs. Besides monitoring the earth, this system has the added benefit of ensuring that the correct type of FIBC or plastic liner is being used, and importantly, that it is working within its specification. If a pipeline is made from insulating plastic or lined metal, its contents will be prevented from dissipating static electricity through the pipe wall and back to earth. However, by introducing a static-dissipative Grounding Paddle between each flange connection, with an external bond to the grounded metal pipe or other suitable earth, static dissipation paths along the length of the pipe are provided. A complete range of Grounding Paddles is now available for many pipe diameters to ensure that the contents of lined pipes can dissipate their static, whilst moving along the pipe.

Next generation of Earth-Rite static grounding sytems

October 7th, 2009

Mr. David Stubbings, SIRA certification manager, with Mr. Ernest Kochmann, CEO of Newson Gale, cutting the ribbon at the official launch of Newson Gale's next generation of Earth-Rite static grounding systems.

Mr. David Stubbings, SIRA certification manager, with Mr. Ernest Kochmann, CEO of Newson Gale, cutting the ribbon at the official launch of Newson Gale's next generation of Earth-Rite static grounding systems.

Newson Gale has released their next generation of ATEX and IECEx certified Earth-Rite® hazardous area static grounding systems. The new systems feature a cluster of bright pulsing green LEDs which provide attention grabbing indication to personnel that a positive ground condition is established for the duration of the transfer process. The new system electronics, which are housed in a IIC EX(d) enclosure as standard, have a certified operating temperature range of -40°C to + 55°C which means the new systems can be installed in the harshest operating environmental conditions without any additional protection or modification. In the world-wide chemical and process industries, Earth-Rite® static grounding systems are a well established key protocol for preventing fires and explosions occurring from electrostatic (spark) discharges during the transfer, processing and handling of flammable or combustible liquids, gases and powders. The upgraded and enhanced features of the new Earth-Rite RTR™ and Earth-Rite PLUS models herald the first wave of a radical advancement in static grounding technology designed to provide the user with multiple benefits in operation, safety and maintenance.

IECEx / ATEX / SIL 2 certified static grounding systems

IECEx / ATEX / SIL 2 certified static grounding systems

Designed specifically for minimising the hazards of static ignitions during Road Tanker Truck loading and unloading, the patented Earth-Rite® RTR provides operators with automatic and failsafe static ground verification and tanker truck recognition checks, ensuring product transfers cannot take place unless these parameters are tested and verified. The Earth-Rite PLUS provides protection for all conductive (metal) items, including drums, vessels, IBCs, mobile tanks and railcars. In addition, both systems include a pair of voltage free contacts that engage only when the resistance to ground is tested and verified to be less than 10 ohms, a feature which enables customers and specifiers demonstrate compliance with globally recognised standards for static control, including Cenelec CLC/TR: 50404 and NFPA 77.

 

Both systems are certified to IECEx and ATEX standards for installation and use in all common hazardous areas, including the very highest gas group approvals (EEx d (ia) IIC T6). Power supply units may be selected from 220/240VAC or 110/120VAC and are suitable for operating temperatures from – 40 deg C to + 55 deg C. The Earth-Rite PLUS and Earth-Rite RTR have been assessed for functional safety and received a SIL 2 rating according to IEC 61508.

All units are compact and easy to install and maintain, and are shipped complete with a detailed installation manual together with optional installer’s kit containing cable glands, wiring and other useful items, while on-board diagnostic “self-checking” electronics makes initial set-up and commission straightforward. The Intrinsically Safe Ground Connection Junction Box, together with “Quick Connect” feature on the cable and clamp enhances safety and simplifies on-going maintenance in hazardous areas.

Newson Gale manufactures an innovative and comprehensive range of static grounding equipment for hazardous areas, which is available worldwide via a network of specialist distributors and representatives. To learn more about the Earth-Rite PLUS and Earth-Rite RTR, visit the Newson Gale website www.newson-gale.com or contact your local office.

 

Static spark ignites fire destroying solvent distribution facility

July 3rd, 2009

A U.S Chemical Safety Board investigation into a catastrophic fire, causing the destruction of a chemical distributor’s storage and packaging facility in Des Moines, Iowa, identified the uncontrolled release of an incendive static spark discharge as the source of ignition. The fire resulted in the evacuation of local businesses and significant business interuption costs for the company involved.

The fire originated in the packaging area of the facility and was caused by an uncontrolled discharge of static electricity when a 300 gallon (1100 litre) intermediate bulk container (IBC) was being filled with ethyl acetate.

The CSB’s investigation concluded that an incendive static spark ignited the vapours emanating from the IBC.

The investigation report stated that the IBC, the pump and the weighing scales on which the IBC had been situated were all grounded, however, the nozzle filling the IBC contained isolated conductive parts.

Static electricity accumulated on the isolated component and when enough potential difference occured between the nozzle and IBC, the static electricity discharged to the ground connected IBC, igniting the flammable ethyl ether atmosphere.

The ignition of the flammable atmosphere caused the filling nozzle to dislodge itself from the IBC and it continued discharging the ethyl ether into the fire, spreading to the rest of the storage area which contained flammable and combustible materials.

Click on link to view the CSB Report.

Controlling Static Hazards:
To prevent uncontrolled discharges of static electricty all conductive parts of the system, including the container being filled, pipes, pumps and nozzles, should be properly grounded to international guidelines (NFPA 77 and CENELEC CLC/TR:50404).

Material defined as conductive or static dissipative within potentially flammable or explosive atmospheres should be used wherever possible.

Filling flow rates should be controlled and splash filling should be avoided (guidance notice 51a issued by the Solvent Industry Association provides advice on this).

Only equipment certified for use within flammable/explosive atmospheres (for example equipment approved by ATEX/FM/CSA) should be used.

The free Newson Gale Grounding and Bonding Applications Handbook provides illustrations of best practice solutions to a broad range of static hazards.

Bond-Rite REMOTE new additions

July 3rd, 2009
Bond-Rite REMOTE GRP indicator station

Bond-Rite REMOTE GRP indicator station

The Bond-Rite REMOTE range has been enhanced with the addition of wall-mounted glass-reinforced plastic (GRP) indicator stations, for installation in hazardous processing areas.

The GRP indicator station is suitable for mounting in processing areas that do not require anti-contamination or anti-corrosion capability. The well established stainless steel indicator stations will continue to be available to cater for hygenic and corrosive environments.

The new GRP indicator station carries the same circuit-monitoring electronics and green flashing LED of the current Bond-Rite range, informing operators when a safe ground connection has been established with process equipment at risk of accumulating hazardous levels of electrostatic charge.

With the recently enhanced PCB boosting the useful lifetime of the battery, the battery-powered unit provides a good alternative to intrinsically safe (IS) mains-powered units requiring only two changes a year when used for up to six hours a day and can be installed and operational in less than 1 hour.

Both the battery-powered and IS/mains-powered Bond-Rite Remote with GRP indicator station are ATEX certified and can be mounted in Zone 0, 20, 1, 21, 2, 22 areas and IIC gas environments.

All Bond-Rite REMOTES are supplied with ATEX and FM approved two-pole clamps and Hytrel cable.

Bond-Rite EZ update

July 3rd, 2009

The heavy duty clamp is fitted with a special jaw grip able to clamp onto virtually any surface, including field-installed grounding rods.

Bond-Rite EZ with medium duty X45-IP

Bond-Rite EZ with medium duty X45-IP

The Bond-Rite EZ portable static grounding and bonding assembly is now available equipped with the option of Heavy Duty and Medium Duty Stainless steel clamps.

This robust clamping mechanism, combined with sharp tungsten carbide teeth, penetrates through even the heaviest build-up of paint, coatings, corrosion, or other insulating deposits.

The EZ clamp  is a self-contained, easy-to-use device that provides, and continuously verifies, a low-resistance bonding connection.

In service it signals the existence of a safe connection to ground - less than 10 ohms - through a flashing green LED indicator on the handle of the monitoring clamp.

There are numerous operations in industry, transportation and emergency response where it is necessary to establish a low-resistance bond or connection to a local ground point, especially where vehicles such as vacuum trucks or a variety of other mobile or portable equipment are employed.

The self-contained Bond-Rite EZ is available in a range of options, with 5m or 10m retractable Cen-Stat cables, or with portable cable reels with up to 100ft capacity.

The Bond-Rite EZ is ATEX  certified as intrinsically safe and suitable for use in all flammable gas, vapour and combustible dust atmospheres. It also carries the equivalent FM and CSA approvals for all hazardous locations.

The recently enhanced PCB now enables the battery to power the EZ for up to a year (based on typical cycle of 3hrs use per day over a five-day week).

Free Grounding + Bonding applications handbook

July 3rd, 2009
Free Grounding and Bonding Applications Handbook

Free Grounding and Bonding Applications Handbook

Register now for your FREE copy of the updated Newson Gale Grounding and Bonding applications handbook, a practical guide to static electricity control in hazardous areas.

The Handbook is a practical guide for engineers and plant managers to controlling the hazards associated with uncontrolled discharges of static electricity within flammable and explosive atmospheres.

The Handbook contains clear and concise illustrations of solutions to a wide range of electrostatic hazards ranging from the grounding of drums and IBCs to the static grounding and interlocking of road tankers.

Static grounding and bonding solutions are supported by relevant quotes from NFPA 77 and Cenelec CLC/TR 50504, the internationally recognised standards that recommend Best Practice for static control, ensuring that Best Practice compliance can be demonstrated by the solutions recommended in the Handbook.

Additional helpful information on hazardous area zoning, the range of gases and dusts that can be ignited by electrostatic charges and static safety checklists are available for reference within the Handbook.

Register now for your FREE copy of the Grounding and Bonding Applications Handbook by ticking the request on our Quick Enquiry box.

Tanker Truck Grounding System Protects Three Ways

March 1st, 2008

The new code-compliant Earth-Rite RTR(TM) system from Newson Gale is based on triple technology to ensure safe static grounding during transfer of flammable products to or from a tanker truck.

Earth-Rite RTR

Earth-Rite RTR

Called TRI-Mode(TM) technology, the new system electronics confirms a positive connection between the truck and the RTR system and confirms a positive connection between the truck and ground, then constantly monitors both connections throughout the transfer process. Transfer cannot begin until all three modes have confirmed the safety of the connections and transfer will be interrupted should the system sense a connection resistance of more than 10 ohms.

Unlike conventional grounding apparatus, the Earth-Rite RTR system provides true failsafe grounding confirmation using patented intrinsically safe electronics and a universal ground clamp. Importantly, the assurance of a low-resistance connection specifically from truck to ground eliminates the bypassing of a grounding system by an accidental connection to the loading gantry or other metallic elements of the facility.

 

 

The system has been tested by independent examiners and is approved for mounting in SIL2 rated environments. Code compliance includes an Ex acceptance, FM and ATEX approval while conforming to best practice guidelines of NFPA 77 and CENELEC 50504, ensuring that rubber-tire transport trucks are properly grounded before and during transfer of flammable liquids. Also, an RTR system can be mounted at remote loading stations and connected to local verified ground point, making significant savings possible in terms of both installation and maintenance costs.

The Earth-Rite RTR(TM) static grounding system for tanker trucks is just part of the Cenelectrex® range of static grounding and bonding equipment available from Newson Gale Inc., the Lakewood, NJ based specialists in static control for hazardous areas. To see a demonstration of the new systems, visit our booth at ILTA 2008 (booth # 550)

For additional information, contact: Newson Gale Inc., 1072 Madison Ave., Lakewood, NJ 08701. Phone: 732-987-7715.
E-Mail: info@newson-gale.com. Website: www.newson-gale.com

Static Grounding for Pharma Applications

November 1st, 2007

New VESF Series stainless steel Quick Connectors are the latest addition to the Cenelectrex range of static earthing equipment specifically designed to meet the demanding standards of cleanliness and corrosion resistance within hazardous area operations in the pharmaceutical industry.

The VESF Series stainless 2 pole plug and socket connectors allow easy, positive and secure connections to be made to removable plant items that need to be earthed and monitored during operations. They are ideal for use with plant items that need to have a temporary or semi-permanent connection to earth, such as mobile vessels, product bowls, pump carts and other removable plant sections.

The distinctive three pin configuration of the unit ensures that they cannot be confused with or connected to plant electrical circuits, and the matching male/female connection means the static earth can only be applied to the intended plant item. Using screw terminals, no hot working is required for initial installation or maintenance. Both plug and socket come with covers to ensure that when not in use they can be sealed off to prevent liquid, dirt or product ingress.ss-connector_fed0510-copy

Designed to compliment the extensive range of stainless accessories that make up the Cenelectrex Earth-Rite Multipoint range of monitoring units, the stainless connectors have been assessed by a notified body as suitable for connection to Intrinsically Safe monitoring circuits, in compliance with the ATEX directive.

Other stainless accessories recently added to the range include an indicator LED light which can be mounted in the hazardous area to give local notification of a positive earth connection. These new items compliment the range of stainless junction boxes and clamps, which make for a comprehensive range to suit the needs of the pharmaceutical industry.

The new Stainless Steel Quick Connectors are ideal for use with the Earth-Rite Mulitpoint, which is specially designed to monitor earth connection and bonds on mills, spray dryers, filters, mixing and similar items such as associated conveying lines where static build up in combustible or flammable areas may lead to catastrophic fires or explosions.

For additional information, contact: Newson Gale Inc., 1072 Madison Ave., Lakewood, NJ 08701.

Phone: 732-987-7715. E-Mail: info@newson-gale.com

Static Grounding and Bonding Assembly is Completely Portable

February 1st, 2007

A completely portable, self-testing grounding and bonding assembly, the Bond-Rite EZ from Newson Gale Inc. makes it possible to establish and verify a proper low-resistance connection to safely dissipate static electricity in hazardous locations.

The new assemblies meet the need for safe, convenient grounding where more permanent solutions are not feasible, especially in mobile or portable equipment whose operation requires static electric discharge protection. Among these are applications in the transportation of flammable liquids, powders or gasses or for emergency response vehicles, as well as many other instances where it is necessary to establish a low-resistance bond or connection to a local ground point for mobile vehicles or portable equipment. In these cases it is time consuming and often impractical to install a permanent ground connection or to set up and test a conventional temporary bond. In these situations, the Bond-Rite EZ offers a self-contained, easy to use device, which provides and continuously verifies a low-resistance bonding connection while displaying a healthy condition through a flashing green LED indicator on the handle of the monitoring clamp (less than 10 Ohms resistance).

Bond-Rite EZ with X45-IP clamp

Bond-Rite EZ with X45-IP clamp

A safe connection is ensured by the strong clamping mechanism combined with sharp tungsten carbide “tooth contact points” that are able to penetrate even the heaviest build-up of paint, coatings, corrosion, or other insulating deposits.

Bond-Rite EZ units are approved as Intrinsically Safe Devices by Factory Mutual and CSA for Class I, II & III, Div 1 & 2, hazardous locations (all gas groups). The unit also has European ATEX approval, and is powered by a replaceable Lithium Manganese battery, which provides up to 600 hours use when continuously connected, with a shelf life of up to 10 years. They are available in a range of options, with 10, 16 or 32ft retractable Cen-Stat® cables, or portable cable reels with up to 100 ft capacity.

The Bond-Rite EZ is just part of the Cenelectrex® range of static grounding and bonding equipment available from Newson Gale, Inc., the Lakewood, NJ based specialists in hazardous area static control.

For additional information, contact: Newson Gale Inc., 1072 Madison Ave., Lakewood, NJ 08701. Phone: 732-987-7715. E-Mail: info@newson-gale.com. Website: www.newson-gale.com

Static Grounding & Bonding Clamps and Assemblies Are FM Approved and ATEX Compliant

January 1st, 2007

The latest FM and ATEX approved stainless steel static grounding and bonding clamps and retractable cable assemblies from Newson Gale Inc. are specifically designed to dissipate static electricity in hazardous areas. They provide a sure, effective connection to ground for portable and mobile plant equipment and containers. All units are Factory Mutual (FM) Approved and ATEX Compliant, combining extremely low electrical resistance with high levels of mechanical strength.

They are available as complete assemblies with a bonding clamp and a high-performance retractable anti-static cable, or as separate items for self-assembly. Common applications include flammable liquid containers, drums, totes, IBC’s, vessels, mobile tanks and more. For extremely safety-critical applications, or where there is a need for constant monitoring of static grounding & bonding conditions, Bond-Rite Intrinsically Safe Self Testing Clamps and Earth-Rite Static Ground Monitoring and Interlock Systems are available, which provide visual verification and control capability.

VESX90 & VESX45 Grounding Clamps

VESX90 & VESX45 Grounding Clamps

FM testing and approvals for Cen-Stat Stainless Steel Clamps include meeting standards for electrical resistance, clamping force, vibration test and mechanical strength. The clamps have sharp, hardened contact tips for penetrating through paint, rust, resins, and other insulating layers. Self retracting cables are typically 16 feet in length with a 10:1 ratio with excellent flexibility and memory. Optional lengths include 10, 32 and 48 feet. All are proven to maintain their shape after at least 20,000 continuous extensions. Further, their chemical and abrasion-resistant anti-static coating prevents surface charge build-up.

In flammable/combustible atmospheres, national and Industry operating guidelines require all conductive/metallic items of the plant to be properly bonded and grounded. The consequences of an incendiary static spark in a hazardous atmosphere are simply too serious to leave to simple or non-approved devices that may not provide adequate protection in a given application. The unique Cenelectrex system offers a combination of features that provides the user with an assembly proven to perform in all common hazardous area applications.

 

 

FM & ATEX Approved Clamps and Assemblies are just one part of the comprehensive range of static grounding and bonding equipment available from Newson Gale Inc., the Lakewood, NJ based specialists in static control for hazardous areas.

For additional information, contact: Newson Gale Inc., 1072 Madison Ave., Lakewood, NJ 08701.

Phone: 732-987-7715. E-Mail: info@newson-gale.com. Website: www.newson-gale.com